- Interface error code
8388608
The address of the incoming parameter is empty.
8388609
The incoming parameter is invalid.
8388610
This function is not implemented.
8388611
Get the instruction header of the final picture to be printed is empty.
8388612
Get the structure used to configure the print instruction is empty.
8388613
Get thread related structure for combined print configuration is empty.
8388614
Timeout waiting for ‘ready to print’ status.
8388615
Receive buffer is too small.
8388616
Character conversion failed.
8388617
Get the instruction header of the final picture to be printed is empty.
8388618
The incoming parameter is out of range.
8388619
Dynamic link library is not initialized, please initialize first.
8388620
Dynamic link library customization information loading failed.
8388621
The dynamic link library has been initialized. There is no need to repeat initialization.
8388622
Failed to call system API.
8404992
Printer name not found.
8404993
The printer device is not online
8421376
There is an error in the printer. Please check the error information on the printer panel or call interfaces such as D300kpqueryprtstatus and D300kptranslateprtcode to obtain the error information of the printer.
8421377
The printer is busy. It may enter setup mode or be in the process of printing.
8421378
The card box is empty. Please put the card in the card box.
8421379
There is already a card inside the printer.
8421380
There is already a card in the card reader.
8421381
No card inside the printer.
8421382
Card jam.
8421383
No card inside the card reader.
8421384
The card receiving box is full or the card receiving box is pulled out.
8421385
The printer is in setup mode, please exit setup mode first.
8421386
There is no such main status code in ‘D300_cfg’.
8421387
There is no such warning code in ‘D300_cfg’.
8421388
There is no such error code in ‘D300_cfg’.
8421389
The function to get status description information cannot find the status code in ‘D300_cfg’.
8421390
The location of the card inside the printer is unknown.
8421391
The card clamping function of rear card output is not applicable to the rear connected 3-in-1 card reader.
8421392
Currently, it is not in the rear card holding status.
8421393
The printer does not have a 3-in-1 card reader. Please ensure that the printer hardware status is correct.
8421394
Timeout waiting for the card to reach the printing position.
8421395
Timeout waiting for the card to reach the contact position.
8421396
Timeout waiting for the card to reach the non-contact position.
8421397
Timeout waiting for the card to reach the 3-in-1 position.
8421398
Timeout waiting for the card to reach the turn-overor position.
8421399
The printer does not have a contact card reader, please make sure the printer hardware status is correct.
8421400
The printer does not have a contactless card reader, please ensure that
the printer hardware status is correct.
8421401
The printer is currently holding the card.
8421402
Currently, it is not in the status of holding the card at the front exit.
8421403
The printer does not have a magnetic stripe reader, please ensure that
the printer hardware status is correct.
8437760
There is no corresponding resolution type.
8437761
The printer does not have a turn-overor.
8437762
This ribbon type is not implemented.
8437763
The offset of half grid ribbon cannot exceed 43.0106 mm.
8454144
Failed to open XML configuration file. Please check whether the file
exists.
8454145
Cannot find a root element of ‘Direct300kp_sdkcfg.xml’, please confirm
whether it is up-to-date.
8454146
Cannot find an element of ‘Direct300kp_sdkcfg.xml’, please confirm
whether it is up-to-date.
8454147
There is a node name mismatch in ‘D300_cfg’.
8454148
Error parsing ‘D300_cfg’ configuration file.
8454149
The card reader manufacturer is not supported currently.
8454150
Error decrypting printer status code table.
8454151
The reader option in the ‘Direct300kp_sdkcfg.xml’ configuration file is not configured as a 3-in-1 reader.
8454152
The reader option in the ‘Direct300kp_sdkcfg.xml’ configuration file cannot be configured as a 3-in-1 reader.
8454153
Failed to verify the password of ‘D300_cfg’ configuration file.
8454154
Illegal value of configuration item in ‘Direct300kp_sdkcfg.xml’.
8454155
Cannot find a root element of ‘D300_Cfg’, please confirm whether it is up-to-date.
8454156
Cannot find an element of ‘D300_Cfg’, please confirm whether it is up- to-date.
8454157
The .img file does not match, please confirm whether it is up-to-date.
8454158
The self-test information of dynamic link library is missing.
8454159
The special code of the project in the self-test information of the
dynamic link library does not match.
8454160
The version number of the project in the self-test information of the
dynamic link library does not match.
8486912
A program based on this dynamic link library is already running.
16777216
Invalid function caused by incorrect resolution
16777217
Out of range parameters
16777218
DSDirectDrawIsNull is empty
16777219
The pointer is null
16793600
Width of the image’s ymc-color does not match with the ymk resolution
16793601
Width of the image’s k-color does not match with the k resolution
16809984
Duplex option is not installed
16809985
The offset of the half-grid ribbon should not be greater than 43.0106
mm16809986
The ribbon extension setting structure returns null
16809987
No corresponding resolution type
16809988
The corresponding filmopt key value is not set
16826368
Failed to get compressed length
75497472
The incoming pointer is null,The address of the passed in parameter is null
75497473
Module length is null,Null character of the passed in module
parameter
75497474
Module length too long,The passed in module parameter length is too long
75513856
Log path does not have access rights
75530240
Write log mode error
75530241
Failed to get thread context information
75530242
Failed to open thread file
75530243
Failed to open global log file
75546624
The input format string is empty
75546625
Error formatting string
75563008
The input text string is empty
75563009
Unicode transcoding failed
75563010
The log file is not open
75563011
Write file error
83886080
The selected printer is not a USB printer, and USB communication is
used by the interface error
83886081
Not have Enumerate to USB printer
83886082
The USB printer descriptor passed in is empty
83886083
USB communication write or read data pointer is null
83886084
USB anti pulse mode communication failed, at opendevice
83902464
The selected printer is not a com printer. Com communication is used
due to interface error
83902465
Not have Enumerate to Serial port printer
83902466
The Serial port printer descriptor passed in is empty
83902467
Serial communication write or read data pointer is null
83918848
The selected printer is not a LPT printer. LPT communication is used due
to interface error
83918849
Not have Enumerate to LPT printer
83918850
The LPT printer descriptor passed in is empty
83918851
LPT communication write or read data pointer is null
83935232
The selected printer is not a TCP printer. TCP communication is used due
to interface error
83935233
Not have Enumerate to TCP printer
83935234
The TCP printer descriptor passed in is empty
83935235
TCP communication write or read data pointer is null
83951616
Unknown port type(Check whether a printer has been selected after
enumeration)
83951617
The internally saved enumeration list does not have this printer(Check
re enumeration)
83951618
The parameter pointer is null
83951619
Be careful this command has no return,No reading is required after
writing
83951620
The current thread does not select a printer,Please select a printer
and try again
83951621
Current instruction header mismatch,Please resend and receive data
83951622
buffer too small,Please adjust the buffer size
83951623
TLS buffer exceeded
83951624
TLS buffer not created
83951625
An empty handle was used
83951626
Failed to request resource lock
83951627
Failed to get TLS handle
25165824
Parameter buffer too small
25165825
The passed in parameter is invalid
25165826
This function is not implemented
25165827
The parameter format is not supported or the parameter format is
incorrect
25165828
Failed to apply for buffer
25182208
Failed to open USB port handle
25182209
Failed to Close USB port handle
25182210
USB failed to send data
25182211
USB asynchronous write data event object wait failed
25182212
The returned value of USB asynchronous write data is not error_ IO_ PENDING
25182213
USB data reading failed
25182214
USB asynchronous data read event object wait failed
25182215
The returned value of USB asynchronous data reading is not error_ IO_ PENDING
25182216
Hid failed to send and receive data
25182217
usb device has Disconnected
25198592
WSAStartup Network communication initialization error
25198593
This computer network library does not support the target version of 2.2
25198594
Socket initialization failed
25198595
Tcp select timeout
25198596
The socket is not open
25198597
Socket sending failed
25198598
socket error
25198599
socket close failed
25198600
WSAStartup Initialized network library version is not 2.2
25198601
TCP setting non blocking IO failed
25198602
TCP setting blocking IO failed
25198603
TCP and printer failed to establish connection
25198604
Socket receiving failed
25214976
Failed to open the serial port handle
25214977
Get serial port configuration error
25214978
Setting serial port configuration error
25214979
Serial port write failure
25214980
Serial port read failure
25214981
The COM port reads data successfully, but the read data is 0 bytes
25214982
Failed to close the serial port handle
25214983
Com communication write or read data pointer is null
25231360
Failed to open parallel port handle
25231361
Failed to close parallel port handle
25231362
Parallel writing failed
25231363
Parallel port asynchronously writes data. Event object waiting failed
25231364
The return value of parallel port asynchronous write data is not error_ IO_ PENDING
25231365
Parallel port reading failed
25231366
Parallel port asynchronously reads data. Event object waiting failed
25231367
The return value of parallel port asynchronous data reading is not error_
IO_ PENDING
25247744
The device information set handle returned null
25247745
No qualified COM port card reader devices are enumerated
25264128
The cloud control is disconnected from the server
25264129
Cloud control failed to send data
25264130
Timeout during data Reply of cloud control meeting
25264131
Cloud control data unpacking failed
25264132
The received instruction is not required by the current function
25264133
The device is occupied by other remote devices
25264134
Connection between cloud control and server failed
92274688
Failed to create barcode.
92274689
Failed to encode the barcode.
92274690
Failed to generate the barcode.
92274691
The path used to store the generated barcode image does not exist.
92274692
Failed to load the generated barcode image, which may be damaged.
92274693
The incoming parameter is invalid.
92291072
Failed to create QRCode.
92291073
Failed to encode the QRCode.
92291074
Failed to generate the QRCode.
92291075
The path used to store the generated QRCode image does not exist.
92291076
Failed to load the generated QRCode image, which may be damaged.
92307456
Wrong selection of canvas mode for color layer or k-color layer.
92307457
Failed to get screen device context handle.
92307458
Failed to create compatible bitmap.
92307459
Failed to create a compatible device context handle.
92307460
Canvas mode is not set.
92307461
The buffer used to get data is not long enough.
92307462
Failed to load the picture. Please check whether the picture file exists or the format is damaged.
92307463
Failed to initialize image manager during ICM processing.
92307464
This picture index was not found when generating preview or print data.
92307465
System or printer ICM file does not exist.
92307466
The font to be set does not exist.
92307467
The actual format of the picture does not match its current suffix.
92307468
The X and Y coordinates of the content to be drawn exceed the printing area.
92307469
Pointer is null.
92307470
The device context corresponding to the watermark layer is empty.
92307471
No configuration attributes were found in the header information area
of the image file.
92307472
There is a configuration attribute in the header information area of the picture file, but it failed to obtain the configuration attribute.
92307473
The default color management file of this system cannot be supported.
92307474
RSWOP.icm not found.
92307475
The color mode in the iccprofile configuration does not match the one in the picture.
92307476
The resolution of the picture is too large.
92307477
The incoming data is empty.
92307478
Image sharpening failed.
92307479
Invalid parameter.
92307480
Image fusion failed.
92307481
Failed to set the landscape mode. You need to set the landscape mode before creating the canvas.
92307482
Failed to draw watermark.
92307485
Failed to get preview.
100663296
Incoming instruction content is null
100663297
Length of received command is too short. (Probably command is wrong)
100663298
Return instruction format parsing error
100663299
Command hearder of send and receive mismatch
100663300
The pointer is null
109051905
Reader library is not loaded or failed to load
109051906
The path to the card reader dynamic library does not exist
109051908
Failed to open card reader
109051909
Card reader interface error.
109051910
Card in the card reader
109051911
No card in the card reader
109051912
The handle of the card reader is null (check if the card reader has been
successfully opened))
109051913
The handle of the card reader is null (check if the card reader has been
successfully opened)
109051914
Dcrf32 dynamic library does not have this function
109068288
M1 card verification failed (check if password, password type or corresponding sector is correct)
109068289
M1card verification password format is wrong
109068290
Failed to search M1 card.
109068291
Recording in hexadecimal format requires 32 bytes of data
109084672
Failed to setup the current contact card reader
109084673
The user expected length of the reset information is too short
109084674
Failed to reset contact CPU card
109084675
The user expected length of the serial number is too short
109084676
The received pointer of reset information or serial number is null
109084677
RF off failure of non connected CPU card
109084678
RF reset failure of non connected CPU card
109084679
Card search request, card conflict prevention and card selection failed
109084680
Non contact CPU card reset failed
125829120
Pointer is null
125829121
invalid parameter
125829122
The length actually received is less than the expected length
125829123
Receive cache too small
125845504
Failed to receive ACK control character
125845505
Failed to receive EOT
125845506
Receiving ACK control character timeout
125845507
Receiving NAK control character timeout
125845508
Failed to reply ACK or NAK control character timeout, Neither ack nor NAK
125861890
Failed to receive STX control character
125861891
Failed to receive length field
125861892
Failed to obtain length after receiving data
125861893
Magnetic reading information does not exist STX
125861894
Track data length out of range
125861895
The calculated CRC is inconsistent with the CRC read back
125861896
Command execution failed. Please check the track return data for details
125861897
Unknown result
125861898
Card swiping failed
125861899
Invalid track data. Please check the data - Printer panel coding
Master status code
LCD prompt character (main status)
1000
Unknown status
1001
Initialize
1002
Ready
1003
Card Feed
1004
Printing Yellow
1005
Printing Magenta
1006
Printing Cyan
1007
Printing Black
1008
Printing Black2
1009
Printing Overcoat
1010
Erase/Print
1011
Printing Pearl
1012
Printing UV
1013
Reverse
1014
Card Ejection
1015
Cleaning Now
1016
Option Setting
1017
Power Save Mode
1018
RDID In Mode
1019
RDID Out Mode
1020
FW UpdatIng
1021
Sub FW UpdatIng
1022
Eject Waiting
1023
Card In exit
1024
Making Card
1025
Card In
1026
Indent Print
1027
Magnetic stripe R/W
1028
RFID Check
1029
Ageing
Warning status code
LCD prompt character (warning status)
2001
No warning
2002
Head Heat High
2003
Check Ribbon
2004
RBN near end,Replace
2005
Card NearEnd
2006
Card OverFlow
2007
Feeder Empty
2008
Clean warning
2009
Head Heat Low
2010
Remove Flip Card
Error status code
LCD prompt character (error status)
3001
No Error
3002
Push Set Key
3003
Cover Open
3004
Ribbon End
3005
Invalid Ribbon
3006
Ribbon Jam
3007
Rbn Match Err
3008
Feeder Card Jam
3009
Flip Card Jam
3010
Print Card Jam
3011
EW Jam
3012
Contact-IC Failure
3013
Head Failure
3014
Fan Failure
3015
FPGA Error
3016
EW Error
3017
RFID Auth Error
3018
Rbn Code Invalid
3019
Detect the unlock
3020
Magnet Card Jam
3021
Mag Write Error
3022
Mag Read Error
3024
Flip Failure
3025
Contact-IC Failure
3026
CLESS-IC Failure
3027
Indent Error
3028
FW Download Error
3029
Call Support
3030
Indent Card Jam
3031
Data transmittal error
3032
Please install ribbon